MySling
Lisclare's own range of single-patient-use patient hoist slings. For moving and handling leads, occupational therapists, and infection prevention and control teams.
MySling is Lisclare's own range of single-patient-use hoist slings, and a Class I medical device. Safe working load is 300 kg, rising to 500 kg in XXL sizes. Loop and clip versions fit 2, 4 and 6 point spreader bars, subject to risk assessment. The slings are not launderable and carry a wash indicator.
At a glance
| MySling | Source | |
|---|---|---|
| Brand owner | Lisclare Limited. MySling is Lisclare's own brand. Lisclare is the legal manufacturer and places the product on the market. Production is contracted to a third-party manufacturer operating an ISO 13485:2016 quality management system, alongside ISO 9001 for quality management and ISO 14001 for environmental management. | Declaration of Conformity SL_MS_DC_02, v3.0, 1 September 2025 |
| Use type | Single-patient-use. Patient-specific, and not launderable. It may be reused with the same patient. | Declaration of Conformity SL_MS_DC_02, v3.0, 1 September 2025 |
| Safe working load | 300 kg. 500 kg in XXL sizes. | MySling loop Instructions for Use SL_MS_L_MI_03 |
| Sizes | XXS, XS, S, M, L, XL, XXL. The range carried varies by sling type. | Declaration of Conformity SL_MS_DC_02, v3.0, 1 September 2025 |
| Fabric | 70% polyester, 30% viscose. Webbing straps 100% polypropylene. | MySling loop Instructions for Use SL_MS_L_MI_03 |
| Attachment | Loop and clip versions. | Declaration of Conformity SL_MS_DC_02, v3.0, 1 September 2025 |
| Spreader bars | Loop slings fit 2, 4 and 6 point loop-and-hook systems, subject to risk assessment. | MySling loop Instructions for Use SL_MS_L_MI_03 |
| Wet and bathing use | Safe to use in a bathroom, shower or toileting environment, and safe to use when wet. | MySling loop Instructions for Use SL_MS_L_MI_03 |
| Laundering | None. The sling must not be machine washed, and must not be used after machine washing. It can be spot cleaned. | MySling loop Instructions for Use SL_MS_L_MI_03 |
| Recommended replacement | Replace after 6 months of use, and at any point it shows wear or damage. | MySling loop Instructions for Use SL_MS_L_MI_03 |
| Device class | Class I medical device, self-declared. Both CE marked (EU MDR 2017/745) and UKCA marked (UK MDR 2002 as amended). | Declaration of Conformity SL_MS_DC_02, v3.0, 1 September 2025 |
| Product standard | ISO 10535:2021, hoists for the transfer of persons. This is the primary product standard applied, covering structural integrity, load capacity, attachment systems and labelling. | Declaration of Conformity SL_MS_DC_02, v3.0, 1 September 2025 |
The range
14 MySling products, grouped by sling type.
| Sling | Type | Attachment | Safe working load |
|---|---|---|---|
| ActiveBelt | Active belt | loop | 300 kg |
| Amputee (clip) | Amputee | clip | 300 kg |
| Amputee (loop) | Amputee | loop | 300 kg |
| Hammock (loop) | Hammock | loop | 300 kg |
| HighBack (clip) | HighBack | clip | 300 kg |
| HighBack (loop) | HighBack | loop | 300 kg |
| Hygiene (loop) | Hygiene and toileting | loop | 300 kg |
| MySling LimbLifter | Limb lifter | loop | 300 kg |
| MySling Repo Sheet | Repositioning sheet | Not applicable | 300 kg |
| Sit-to-stand (clip) | Sit-to-stand | clip | 300 kg |
| Sit-to-stand (loop) | Sit-to-stand | loop | 300 kg |
| MySling for Sara Plus | Sit-to-stand | loop | 300 kg |
| Universal (clip) | Universal | clip | 300 kg |
| Universal (loop) | Universal | loop | 300 kg |
Standards and testing
The Declaration of Conformity applies the following. Lisclare is the legal manufacturer, and conformity is self-declared, which is what Class I permits under both EU MDR Annex IV and the UK Medical Devices Regulations.
| Standard | What it covers |
|---|---|
| ISO 10535:2021 | Assistive products. Hoists for the transfer of persons. Requirements and test methods. The primary product standard, covering body-support units. |
| EN ISO 14971:2019 + A11:2021 | Application of risk management to medical devices. |
| ISO 20417:2021 | Information to be supplied by the manufacturer. Replaces the withdrawn EN 1041:2008+A1:2013. |
| EN ISO 15223-1:2021 | Symbols used on device labels and packaging. |
| ISO 3758:2012 | Textile care labelling by symbols. |
| EN 1021-1 and EN 1021-2 | Fire retardancy. Tested under the earlier Quality and Compatibility Statement. |
Testing described in the Quality and Compatibility Statement includes weight testing at 1.5 times the safe working load held statically for 20 minutes, fire retardancy, and laundry tests for shrinkage. Lisclare states it also load-tests when wet and overloads to breaking point for its own quality procedures, beyond what the standard requires.
Sizing
Measure from the coccyx to the top of the head, and across the widest point of the hips. These figures select a starting size. They do not replace an assessment of whether the sling suits the person.
Treat the table below as an example rather than a rule. The figures come from the MySling instructions for use and hold for most of the loop slings in the range. They do not hold for all of them, and they do not apply to the clip slings. Sizing is assessment-driven: somebody has to see the patient.
| Size | Coccyx to top of head | Width at hips |
|---|---|---|
| XXS | 50cm to 54cm | Under 23cm |
| XS | 54cm to 60cm | 23cm to 33cm |
| S | 60cm to 70cm | 33cm to 41cm |
| M | 70cm to 84cm | 41cm to 48cm |
| L | 84cm to 96cm | 48cm to 56cm |
| XL | 96cm to 108cm | 56cm to 66cm |
| XXL | 108cm to 120cm | Over 66cm |
Loop colours
Loop selection is an assessment decision for a moving and handling professional. The standard starting point in the Instructions for Use is blue loops at the shoulders and yellow at the legs. For amputees, the standard is blue at both the shoulders and the legs.
Hoist compatibility
Appendix I of the MySling Quality and Compatibility Statement lists the passive lifts and active standing aids MySling has been tested with: 58 models across 14 manufacturers.
Arjo, BHM, Chiltern, Drive Medical, Ergolet, Etac, Guldmann, Handicare, Harvest Healthcare, Hill-Rom, Humancare, Invacare, Joerns, Molift.
Which MySling fits my hoist?
Pick your hoist and we will tell you which fitting it takes and which slings match. If you already know whether your spreader bar takes loops or clips, skip the hoist.
Fitting is what the widget can tell you. Sling type, size and safe working load follow an assessment of the person by a competent assessor, and the working limit is the lower of the sling's and the hoist's. Hoist not listed? Tell us the model and we will check. How to choose a hoist sling.
Lisclare's own position, stated in that document, is that a hoist manufacturer's reluctance to recognise alternative slings may be commercial rather than clinical, and that what is actually required is a thorough written risk assessment by a competent assessor. That requirement comes from the Provision and Use of Work Equipment Regulations 1998.
The wash indicator
Every MySling carries an indicator that changes appearance once the sling has been through a machine wash. A sling that has been washed must not be used again.
This matters because the common failure is not a decision, it is a laundry round. A single-patient-use sling that goes through a wash looks much the same afterwards. The indicator means the sling tells you, rather than the ward relying on someone remembering which slings are launderable.
Before every use
From the Instructions for Use. This is the check a competent assessor expects to see carried out.
- Check the patient does not exceed the maximum load of either the sling or the hoist, and work to the lower of the two.
- Check the date of first use and replace the sling if it has been in use for more than 6 months.
- Check the wash indicator. Dispose of the sling if it has been machine washed.
- Check the lifting equipment has fixing points suitable for the sling type.
- Visually inspect the fabric, seams, stitching, webbing straps and clips. Dispose of the sling at any sign of damage or excessive wear.
- Where plastic stay head supports are fitted, check they are enclosed in their pockets.
Regulatory identity
From the Declaration of Conformity. These are the identifiers a procurement or governance team is asked for, and they are rarely published anywhere they can be found.
| Legal manufacturer | Lisclare Limited, 38 Montgomery Road, Belfast, BT6 9HL |
|---|---|
| Company registration | NI031180 (Companies House, Northern Ireland) |
| Basic UDI-DI | 506075020MYSLINGLR |
| EUDAMED SRN | XI-MF-000031978 |
| MHRA account number | 2126 |
| EMDN code | V0805038002, rigid supports for lifts (harnesses) |
| GMDN code | 37480, general-purpose patient lifting system sling/harness |
| Classification | Class I, EU MDR 2017/745 Annex VIII. UK MDR 2002 as amended. |
| Market access | Established in Northern Ireland under the Windsor Framework. CE valid for Northern Ireland and the EU, UKCA valid for Great Britain. |
Questions
- Can MySling be used on another manufacturer's hoist?
- Yes, subject to a written risk assessment by a competent assessor, which is what PUWER 1998 requires. Appendix I of the MySling Quality and Compatibility Statement lists the hoists and standing aids MySling has been tested against. No regulation obliges you to buy slings from the maker of your hoist.
- Is MySling single-patient-use or disposable?
- Single-patient-use. It is issued to one patient and reused with that patient, which is not the same as single-use. It is not launderable. Lisclare's own description is “lasting disposable”, and the practical rule is one patient, no machine washing, replace after six months.
- What happens if a MySling is machine washed by mistake?
- It must not be used again. Every MySling carries a wash indicator that changes appearance once the sling has been through a machine wash, so the sling tells you rather than relying on someone remembering. Check it as part of the pre-use inspection and dispose of the sling if it has changed.
- What is the safe working load of a MySling?
- 300 kg across the range, rising to 500 kg in XXL sizes. The limit that applies in practice is the lower of the sling's safe working load and the hoist's, so check both before every transfer rather than assuming the sling is the constraint.
- Which loops should be used on the spreader bar?
- Selection is an assessment decision for a moving and handling professional. The standard starting point in the Instructions for Use is blue loops for the shoulders and yellow for the legs. For amputees the standard is blue loops for both shoulders and legs.
Trials and samples
Lisclare holds a Master Indemnity Agreement with the Department of Health which indemnifies NHS trusts and their employees against liability for damage or injury caused by a fault in the design or workmanship of a Lisclare sling during a trial, or through the use of a sample.
Lisclare references IFA822 for goods on loan to a trust, and IFB822 for samples given to a trust.
Talk to the moving and handling team about a trial, or ask for a sample to assess against your own hoists.
Documents
- MySling Quality and Compatibility Statement, including Appendix I
- Declaration of Conformity, SL_MS_DC_02
- MySling loop Instructions for Use, SL_MS_L_MI_03
- MySling clip Instructions for Use, SL_MS_C_MI_02
- MySling Sit-to-Stand Instructions for Use, loop and clip
- MySling ActiveBelt, LimbLifter and Repo Sheet Instructions for Use
Last reviewed 2026-09-11. Reviewed by Stephen Hall, Managing Director, Lisclare Limited. Pending sign-off.